RADBOOK 201516 ◼  COMPUTED TOMOGRAPHY YesDual Energy 195 ms with iTRIM (120 ms bi-segment)Temporal resolution 64Slices per rotation 20/40Slices per rotation Highlights • Rotation time of up to 0.3 s and 0 MHU STRATON tube with 70 kV • Workflow optimization for more reliable and reproducible scan- ning with FAST CARE technology • Automated kV setting with CARE kV • 3D-guided intervention • Raw-data based iterative recon- struction (SAFIRE) with up to 20 images/s • iMAR (iterative Metal Artifact Reduction) and Dual Energy • Special configuration for dedicated radiation therapy planning • Fully onsite upgradeable to 128 slices with Stellar detector · SOMATOM Definition AS (64-slice configuration)Siemens Up to 100 kWPower 78 cmGantry bore YesDual Energy Highlights • Rotation time of up to 0.33 s and 0 MHU STRATON tube with 70 kV • Workflow optimization for more reliable and reproducible scanning with FAST CARE technology • Automated kV setting with CARE kV • Raw-data based iterative reconstruction (SAFIRE) with up to 16 images/s • iMAR (iterative Metal Artifact Reduction) and Dual Energy • 3D-guided intervention • Fully onsite upgradeable to 128 slices with Stellar detector · SOMATOM Definition AS (20- and 40-slice configuration)Siemens 80 kWPower 78 cmGantry bore YesDual Energy Highlights • Unique eCockpit suite and innovative service for lower TCO • Raw-data based iterative reconstruction (SAFIRE) for up to 60 % dose reduction • FAST solutions to make time-consuming and complex procedures faster and far more intuitive • Efficient gantry design with Illumination Moodlight and an extremely short focal spot to isocenter distance • iMAR (iterative Metal Artifact Reduction) and Dual Energy · SOMATOM Perspective (16- and 32-slice configuration)Siemens 55 kW (112 kW equivalent)Power 16/32Slices per rotation 20 TO 64 SLICES Highlights • 64 and 128 slices imaging • Latest innovations in a 40 mm detector CT • Leadership in advanced cardiac CT • Intelligent cardiac CT with Snapshot • Assist and Snapshot Freeze • Real time recon (55 fps) • Fast acquisitions with high helical pitch (1.531) • Automatic reconstruction with 10 PMR • Up to 500 slices coverage for perfusion • 60% lower CO2 emission and energy saving • Scalable and modular • Compact for easy siting (18 sqm) • Integrated ASiR reconstruction · Optima CT660SGE Healthcare 0.4 s (cardiac 0.35 s)Rotation 40 mm isotropic, 64i – 0.625 mm (overlap), 32i – 0.625 mm, 16i – 1.25 mm, 8i – 2.5 mm, 4i – 5 mm, 2i – 10mm Coverage 64Channels Highlights • PURE ViSION detector • Upgradeable to 0.4 s rotation • 72 cm bore • 2 mm @ 3 HU LCR • AIDR 3D iterative reconstruction • Dose check and report • SURECardio, low dose cardiac (option) • CT DSA with SURESubtraction (option) • SUREFluoro for intervention procedures (option) • SUREXtension, remote access (option) • Reduced energy consumption · Aquilion RXLToshiba 0.5 mmSlice thickness 16/32Slices per rotation 3.2 cmCoverage per rotation 0.5 sRotation speed Highlights • Upgradeable to 0.6 s rotation • 72 cm bore • 2 mm @ 3 HU LCR • AIDR 3D iterative reconstruction • Navi Mode Operation for fast patient throughput • CT DSA with SURESubtraction (option) • SUREFluoro for intervention procedures (option) • 2.9 ton/year reduction of CO2 emission • Minimized energy consumption • Minimum foot print of 10.4 m2 · Astelion Advance EditionToshiba 0.5 mmSlice thickness 16/ /32Slices per rotation 2.0 cmCoverage 0.75 sRotation speed

Pages Overview