Please activate JavaScript!
Please install Adobe Flash Player, click here for download

Radbook 2015

RADBOOK 201512 ◼  COMPUTED TOMOGRAPHY 128Acquired slices/rot128Acquired slices/rot 64/128Slices per rotation Highlights • Rotation time of up to 0.3 s and 0 MHU STRATON tube with 70 kV • Workflow optimization for more reliable and reproducible scanning with FAST CARE technology • Automated kV setting with CARE kV • TwinBeam Dual Energy and iMAR (iterative Metal Artifact Reduction • Raw-data based iterative reconstruction (SAFIRE) with up to 20 images/s • 3D-guided intervention, upgradeable to Stellar detector · SOMATOM Definition AS (128-slice AS+ configuration)Siemens Up to 100 kWPower 78 cmGantry bore YesDual Energy VOLUME CTS Highlights • 0.28 s rotation speed • Revolutionary Stellar detector: 0.50 mm slices for 0.30 mm spatial resolution • STRATON tube with z-Sharp and 70 kV imaging • Raw-data based iterative reconstruction (ADMIRE) • TwinBeam Dual Energy • iMAR (iterative Metal Artifact Reduction) • Dynamic imaging of up to 48 cm · SOMATOM Definition EdgeSiemens Up to 100 kWPower 78 cmGantry bore YesDual Energy Highlights • Unique eCockpit suite and innovative service for lower TCO • Raw-data based iterative reconstruction (SAFIRE) for up to 60 % dose reduction • FAST solutions to make time-consuming and complex procedures faster and far more intuitive • Efficient gantry design with Illumination Moodlight and an extremely short focal spot to isocenter distance • iMAR (iterative Metal Artifact Reduction) and Dual Energy · SOMATOM Perspective (64- and 128-slice configuration)Siemens YesDual Energy 195 ms with iTRIM (120 ms bi-segment)Temporal resolution 55 kW (112 kW equivalent)Power Highlights • PURE ViSION detector • 78 cm bore • 2 mm @ 3HU LCR • 300 kg patient load table • Lateral table movement (option) • AIDR 3D iterative reconstruction • Adaptive Diagnostics • SEMAR (Metal Artifact Reduction) • Sub mSv Cardiac • Arrhythmia scanning • Isophasic organ perfusion • UltraHelical • Dual Energy at 50 cm FOV (option) · Aquilion ONE ViSION EditionToshiba 0.275 sRotation speed 0.5 mmSlice thickness 640Slices per rotation 16 cmCoverage per rotation Highlights • PURE ViSION detector • Upgradeable to 0.275 s per rotation • 78 cm bore • 2 mm @ 3 HU LCR • 300 kg patient load table • Lateral table movement (option) • AIDR 3D iterative reconstruction • Adaptive Diagnostics • SEMAR (Metal Artifact Reduction) • Sub mSv Cardiac • Arrhythmia scanning • Isophasic organ perfusion • UltraHelical • Dual Energy at 50 cm FOV (option) · Aquilion ONEToshiba 0.35 sRotation speed 0.5 mmSlice thickness 640Slices per rotation 16 cmCoverage per rotation Highlights • PURE ViSION detector • 78 cm bore • 2 mm @ 3 HU LCR • 300 kg patient load table • Lateral table movement (option) • AIDR 3D iterative reconstruction • Iterative bolus tracking • Iterative 3D Fluoro (option) • Adaptive Diagnostics • SEMAR (Metal Artifact Reduction) • Low dose Helical Cardiac Prospective scanning (option) • Dual Energy at 50 cm FOV (option) • 14.8 m2 installation space · Aquilion PRIMEToshiba 0.35 sRotation speed 0.5 mmSlice thickness 80/160Slices per rotation 40Coverage

Pages Overview