Please activate JavaScript!
Please install Adobe Flash Player, click here for download

Radbook 2016

ONCOLOGY CT · · Discovery CT580 RT GE Healthcare 0.35 mm Spacial resolution 16 Slices per rotation 55 / 100 kW Power Highlights • Wide bore geometry (80 cm) • All tables TG66 compliant (225 and 295 kg max) • Up to 40 % dose reduction across the body with integrated ASiR reconstruction* • 4D gating reconstruction on the operator console • Complete and easy to use RT simula- tion planning solution with SIM MD on AW • smartMAR – rawdatabased metal atrefact reduction • Deviceless 4D - breath gating • 80 cm max FOV * Compared to prior generation · · Brilliance Big Bore Philips Highlights • Dedicated RTP features and ­ applications such as TG66 compliant table (295 kg), simulation and marking tools • iPatient – Consistent image quality and improved scan time workflow. • 85 cm gantry opening • 60 cm true scan FOV and extended 70 cm FOV • O-MAR metal artifact reduction for orthopedic implants • 4D respiratory imaging, including phase and/or amplitude binning • iDose4 reconstruction · · SOMATOM Scope Power Siemens 8 m2 System Footprint 12 m2 Installation Area 16 Slices per rotation 50 kW Power Highlights • Leading image quality resulting from high-quality UFC detector material and iterative reconstruction. • Improved visualization thanks to iMAR and extended field of view of 70 cm • More efficient examination procedures with the all-in-one workplace • Comprehensive tumor motion management solution • Optimized TCO due to reduced overhead costs and extended scanner lifetime with eCockpit · · SOMATOM Definition Edge Siemens 78 cm Gantry bore yes Dual Energy 128 Slices per rotation Up to 100 kW Power Highlights • Advanced evaluation of therapy response of tumors and tissues properties thanks to Twin Beam Dual Energy and Adaptive 4D Spiral • Improved visualization thanks to iMAR and extended field of view of 78 cm • Comprehensive tumor motion management solution • Improved process efficiency with a workflow guided RT solution · · SOMATOM Definition AS Open – RT Pro edition Siemens Yes Dual Energy Up to 100 kW Power 80 cm Gantry bore 20 / 64 Slices per rotation Highlights • Leading image quality result- ing from high-quality UFC detector material and iterative reconstruction • Improved visualization thanks to iMAR and extended field of view of 80 cm • Comprehensive tumor motion management solution • Ready for new treatment techniques requiring higher accuracy • Improved process efficiency with a workflow guided RT solution · · Aquilion LB Toshiba 0.5 mm Slice thickness 32 Slices per rotation 3.2 cm Coverage per rotation 0.5 s Rotation speed Highlights • PURE ViSION detector • 90 cm bore • 70 cm FOV • 85 cm extended FOV • 2 mm @ 3 HU LCR • 300 kg patient load table • AIDR 3D iterative reconstruction • SEMAR (Metal Artifact Reduction) • Respiratory gating (option) • Oncology table top (option) • CT DSA with SURESubtraction (option) • SUREFluoro (option) • Reduced energy consumption RADBOOK 2016 23 COMPUTED TOMOGRAPHY  ◼ RADBOOK 201623

Pages Overview