Please activate JavaScript!
Please install Adobe Flash Player, click here for download

Radbook 2016

VOLUME CTS · · SOMATOM Perspective (64- and 128-slice configuration) Siemens Only 18.5 m2 Installation Area 0.39 s equivalent (0.48 s) Rotation speed 64 / 128 Slices per rotation Yes Dual Energy Highlights • Easy user interface with auto- mated procedures • Efficient daily usage through low energy consumption, slim gantry design and Illumination Moodlight • Unique eCockpit suite and innovative service for low TCO • Excellent system performance with fast real-time reconstruction and high image quality at high pitch • iMAR (iterative Metal Artifact Reduction) and fast iterative reconstruction · · Aquilion ONE Toshiba 0.35 s Rotation speed 0.5 mm Slice thickness 640 Slices per rotation 16 cm Coverage per rotation Highlights • PURE  ViSION detector • Upgradeable to 0.275 s / rotation • 78 cm bore • 2 mm @ 3 HU LCR • 300 kg patient load table • Lateral table movement (option) • AIDR 3D Enhanced iterative ­reconstruction • FIRST (Model Based IR, option) • Adaptive Diagnostics • SEMAR (Metal Artifact Reduction) • Sub mSv Cardiac • Arrhythmia scanning • Isophasic organ perfusion • UltraHelical • Dual Energy at 50 cm FOV (option) · · Aquilion ONE ViSION Edition Toshiba 0.275 s Rotation speed 0.5 mm Slice thickness 640 Slices per rotation 16 cm Coverage per rotation Highlights • PURE  ViSION detector • 78 cm bore • 2 mm @ 3HU LCR • 300 kg patient load table • Lateral table movement (option) • AIDR 3D Enhanced iterative ­reconstruction • FIRST (Model Based IR, option) • Adaptive Diagnostics • SEMAR (Metal Artifact Reduction) • Sub mSv Cardiac • Arrhythmia scanning • Isophasic organ perfusion • UltraHelical • Dual Energy at 50 cm FOV (option) · · Aquilion PRIME Toshiba 0.35 s Slice thickness 0.5 mm Slices per rotation 80 / 160 Coverage 40 Rotation speed Highlights • PURE  ViSION detector • 78 cm bore • 2 mm @ 3 HU LCR • 300 kg patient load table • Lateral table movement (option) • AIDR 3D Enhanced iterative recon- struction • Iterative bolus tracking • Iterative 3D Fluoro (option) • Adaptive Diagnostics • SEMAR (Metal Artifact Reduction) • Low dose Cardiac scanning (option) • Dual Energy at 50 cm FOV (option) • 14.8 m2 installation space · · Optima CT660 GE Healthcare 0.35 sec Rotation speed 0.31 mm Spacial resolution 72 / 100 kW Power 64 / 128 Slices per rotation Highlights • Diagnostic power and workflow efficiency, enabling fast, high-quality acquisitions at optimized dose. • Intelligent cardaic CT with SnapShot Assist and SnapShot Freeze • Powered by Smart Technologies • ASiR • SmartMAR - rawdatabased metal artifact reduction 20 TO 64 SLICES · · Revolution EVO GE Healthcare 0.35 sec Rotation speed 0.28 mm Spacial resolution 72 / 400 kW Power 64 / 128 Slices per rotation Highlights • Widest variety of patients and ap- plications, from complex trauma to advanced vascular and perfusion. • Confidence even when performing advanced procedures such as cardiac and TAVI planning • High-resolution at low-dose: Clarity imaging chain with technology inherited from Revolution CT • ASiR-V – up to 82% lower dose* • SmartMAR – rawdatabased metal artifact reduction * Compared to prior generation RADBOOK 2016 16 ◼  COMPUTED TOMOGRAPHY

Pages Overview