◼  COMPUTED TOMOGRAPHY VOLUME CT Philips · iCT Slices per rotation Coverage Power 256 / 128 80mm / 40 mm 120 kW / 100 kW Philips · iCT Elite Slices per rotation Coverage Power 256 80 mm 120 kW Highlights • iPatient – Consistent image quality and improved scan workflow. • High patient eligibility – Bariatric and Pediatric • Low energy imaging for a large number of patients • Low dose coronary CTA for a large number of patients • Low-dose brain perfusion • With iDose4 Premium Package – iDose4 reconstructor including O-MAR • Optional IMR – Iterative Model-based Reconstruction Highlights • New Nanopanel Elite Detector – Enables low dose scanning • iPatient – Consistent image quality and improved scan time workflow Platform for delivering future CT discoveries like IMR • Syncright – CT / Injector integration • IMR – Virtually noise free image quality. 2.7 x improvement in low contrast detectability index • iDose4 Premium Package Philips · Ingenuity Elite Slices per rotation Coverage Power 128 40 mm 80 kW (105 kW Efective) Philips · IQon Spectral CT scanner Highlights • New Nanopanel Elite Detector – Enables low dose scanning • iPatient – Consistent image quality and improved scan time workflow. Platform for delivering future CT discoveries like IMR • Syncright – Appropriate contrast dose with CT / Injector integration • IMR – Virtually noise free image quality. 2.7 x improvement in low contrast detectability index. • iDose4 Premium Package – iDose4 Reconstructor including O-MAR Highlights • The world's first and only spectral detector solution delivering comprehensive, valuable diagnostic and clinical insights. • Improved tissue characterization and visualization • Spectral results 100 % of the time, in one scan • For the most challenging cases, routinely • Fully integrated with your current workflow, from scanner to PACS • And at low dose Siemens Healthineers · SOMATOM Deinition Edge Siemens Healthineers · SOMATOM Deinition AS Dual Energy Slices per rotation Gantry bore Power Yes 128 78 cm Up to 100 kW Dual Energy Slices per rotation Gantry bore Power Yes 128 78 cm Up to 100 kW Highlights • Rotation time of up to 0.3 s and 0 MHU STRATON tube with 70 kV • Workflow optimization for more reliable and reproducible scan- ning with FAST CARE technology • Automated kV setting with CARE kV • TwinBeam Dual Energy and iMAR (iterative Metal Artifact Reduction) • TwinBeam Dual Energy • iMAR (iterative Metal Artifact Reduction) • Dynamic imaging of up to 48 cm Highlights • 0.28 s rotation speed • Revolutionary Stellar detector: 0.50 mm slices for 0.30 mm spatial resolution • STRATON tube with z-Sharp and 70 kV imaging • Raw-data based iterative reconstruc- tion (ADMIRE) 10 • Raw-data based iterative reconstruc- tion (SAFIRE) with up to 20 images / s • 3D-guided intervention, upgradeable to Stellar detector RADBOOK 2017

Seitenübersicht